MELSEC-F
HARDWARE MANUAL
GRAPHIC FX-50DU-TK(S)-C UNITS

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi MELSEC-F FX-50DU-TKS-C

  • Page 1 MELSEC-F HARDWARE MANUAL GRAPHIC FX-50DU-TK(S)-C UNITS...
  • Page 2 If in doubt at any stage during the installation of the FX-50DU-TK(S)-C always consult a professional electrical engineer who is qualified and trained to the local and national standards. If in doubt about the operation or use of the FX-50DU-TK(S)-C please consult the nearest Mitsubishi Electric distributor. •...
  • Page 3 All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
  • Page 4 Graphic FX-50DU-TK(S)-C Units GRAPHIC FX-50DU-TK(S)-C UNITS Hardware Manual Manual number: JY992D64301 Manual revision: Date: January 1997...
  • Page 5 Graphic FX-50DU-TK(S)-C Units Guidelines for the safety of the user and protection of the FX-50DU-TK(S)-C units This manual provides information for the installation and use of the FX-50DU-TK(S)-C units. The manual has been written to be used by trained and competent personnel. The definition of such a person or persons is as follows;...
  • Page 6 Graphic FX-50DU-TK(S)-C Units The following variations of the FX-50DU-TK(S)-C conform to the identified standards;...
  • Page 7: Table Of Contents

    Graphic FX-50DU-TK(S)-C Units Table of Contents 1. Introduction 1.1 The Complete Family Of Graphic Data Access Units ..1-2 1.2 Dimensions and Specifications ....1-3 1.2.1 FX-50DU-TK(S)-C Dimensions .
  • Page 8: Introduction

    Graphic FX-50DU-TK(S)-C Units Introduction Introduction Terminal Layouts Installation Notes Wiring Diagnostics Index 1 – 1...
  • Page 9: The Complete Family Of Graphic Data Access Units

    Graphic FX-50DU-TK(S)-C Units Introduction Introduction This manual covers the hardware specifications and installation instructions for the following graphic data access units: FX-50DU-TK-C (monochrome) FX-50DU-TKS-C (STN; 8 colors) The Complete Family Of Graphic Data Access Units FX-25DU-E FX-30DU-E FX-40DU-TK-E 1 – 2...
  • Page 10: Dimensions And Specifications

    Graphic FX-50DU-TK(S)-C Units Introduction Dimensions and Specifications 1.2.1 FX-50DU-TK(S)-C Dimensions 66 (2.60) (0.22) (4.72) (5.12) 160 (6.30) about 110 (4.33) 170 (6.69) 1.2.2 Unit Characteristics MODEL SCREEN TYPE KEYS IP RATING FX-50DU-TK-C Monochrome LCD Complete Touch 240 dots IP 65 Key operation 15 chars (Based on...
  • Page 11: Unit Accessories

    Graphic FX-50DU-TK(S)-C Units Introduction Unit Accessories Each of the Graphic Data Access Units comes with the following accessories. The battery F -40BL is inside the unit and can be replaced by following the instructions later in this manual (Page 5-4). Figure 1.1 -40BL Mounting brackets and screws (6 of each) are...
  • Page 12: Configuration

    Graphic FX-50DU-TK(S)-C Units Introduction Configuration Product descriptions and connection details are below. Figure: 1.6 Schematic System 1.5.1 Product Description 1.5.2 Connection Details FX-50DU-TK(S)-C Graphic Display Unit FX-40DU-CAB FX, FX or A series to monitor FX-40DU-CAB + FX-20P-CADP , FX , FX series to monitor F2-232CAB or compatible RS232 cable Serial Printer to print data logging and...
  • Page 13: Function List

    Graphic FX-50DU-TK(S)-C Units Introduction Function List The following table shows the various modes and the functions they support. Please refer to the DU software manual for further details. USER SCREEN MODE Activate the user screens MONITOR MODE DEVICE MONITOR Display/set device values ACTIVE STATE MONITOR Monitor STL (States) activity PC DIAGNOSTICS...
  • Page 14: Set-Up Mode

    Graphic FX-50DU-TK(S)-C Units Introduction Set-up Mode As well as the functions listed in section 1.6 the FX-50DU-TK(S)-C can also adjust the following settings direct from the unit. To reach the set-up menu power on the unit while pressing the top left corner of the screen. Used for DU menus and SYSTEM LANGUAGE ENGLISH, JAPANESE...
  • Page 15 Graphic FX-50DU-TK(S)-C Units Introduction MEMO 1 – 8...
  • Page 16: Terminal Layouts

    Graphic FX-50DU-TK(S)-C Units Terminal Layouts Introduction Terminal Layouts Installation Notes Wiring Diagnostics Index 2 – 1...
  • Page 17: Power Terminals

    Graphic FX-50DU-TK(S)-C Units Terminal Layouts Terminal Layouts Following are the power terminals and the communication connectors assignments. Power Terminals Figure: 2.1 FX-50DU-TK(S)-C power terminals The FX-50DU-TK(S)-C power terminal on the back of the unit should be connected to an external 24VDC 24v DC power supply.
  • Page 18 Graphic FX-50DU-TK(S)-C Units Installation Notes Introduction Terminal Layouts Installation Notes Wiring Diagnostics Index 3 – 1...
  • Page 19: Installation

    Installation All the graphic data access units are intended to be installed in a panel and connected to a Mitsubishi PLC mounted inside the panel. Product Outline The figures below show the front and rear views of the FX-50DU-TK(S)-C, indicating the hardware features of the unit.
  • Page 20: Fx-50Du-Tk(S)-C Dimensions

    Graphic FX-50DU-TK(S)-C Units Installation Notes FX-50DU-TK(S)-C Dimensions Dimensions: mm (inches) 66 (2.60) (0.22) (4.72) (5.12) 160 (6.30) about 110 170 (6.69) Environment Specification Table: 3.2 SPECIFICATION. 0 to 40 °C 32 to 104 °F Operating temperature -20 to 60 °C -4 to 140 °F Storage temperature Humidity: No condensation 35 to 85% R.H.
  • Page 21: Data Access Unit Mounting

    Graphic FX-50DU-TK(S)-C Units Installation Notes Data Access Unit Mounting Cut a hole in the panel (1) to the appropriate dimensions as shown below. If required fit the seal (2) before inserting the unit into the panel. Insert the unit (3) squarely into the panel.
  • Page 22: Control Devices

    Graphic FX-50DU-TK(S)-C Units Installation Notes Control Devices The FX-50DU-TK(S)-C uses 8 bit devices and 6 data registers to enable control with the monitored MPU. The meaning of these devices is explained in the following table. Table: 3.3 Control Device Names Bit Devices Description Direction...
  • Page 23 Graphic FX-50DU-TK(S)-C Units Installation Notes MEMO 3 – 6...
  • Page 24 Graphic FX-50DU-TK(S)-C Units Wiring Introduction Terminal Layouts Installation Notes Wiring Diagnostics Index 4 – 1...
  • Page 25: General Wiring

    Graphic FX-50DU-TK(S)-C Units Wiring General Wiring The wiring of the Data Access Units has been designed to be safe and secure by using terminals for the connection of the power supply and D-Shell connectors for all communication cabling. Wiring Cautions •...
  • Page 26 Graphic FX-50DU-TK(S)-C Units Wiring Figure: 4.2 Connection to FX Service Supply Figure: 4.3 Connection to Independent Source Table: 4.1 Feature Table Table: 4.2 Power Supply Specification Ref.No. Spec. 24V DC Programmable Controller (MPU) Power Supply Voltage (+10%, –15%) Comms Cable FX-40DU-CAB Power Supply Ripple 200 mV or less FX-50DU-TK(S)-C...
  • Page 27: Communication Cables

    Graphic FX-50DU-TK(S)-C Units Wiring Communication Cables The Data Access Units are connected to the MPU using the FX-40DU-CAB RS422 cable and to computers and printers using the F -232CAB cable or equivalent. • If the FX-40DU-CAB cable is not connected then a “communication error” may occur. •...
  • Page 28: Diagnostics

    Graphic FX-50DU-TK(S)-C Units Diagnostics Introduction Terminal Layouts Installation Notes Wiring Diagnostics Index 5 – 1...
  • Page 29: Error Messages

    Graphic FX-50DU-TK(S)-C Units Diagnostics Diagnostics This chapter is intended to aid a trained engineer in fault finding and trouble shooting. Error Messages Screen messages and there meanings (in alphabetical order). BAD OBJECT EXISTS - - - XXXXXXX An incorrectly defined object (of type XXXXXXX) has been found when viewing a screen using test mode.
  • Page 30 Graphic FX-50DU-TK(S)-C Units Diagnostics PLC PROGRAM IS DESTROYED The program in the MPU has become corrupted. • Re-load the program in to the MPU. SET DEVICE IS INCORRECT Device Number entry: An invalid device number has been specified. Example: A word device (D) instead of a bit device (X,Y,etc.).
  • Page 31: Maintenance

    Display and Back Light The LCD life is about 50,000 hours and the back light life is about 10,000 hours operation. • User replacement is not possible. Please refer to your nearest Mitsubishi service centre. • For this reason it is recommended that a back light saving technique is used to extend the operational life time of the back light.
  • Page 32: Index

    Graphic FX-50DU-TK(S)-C Units Index Introduction Terminal Layouts Installation Notes Wiring Diagnostics Index 6 – 1...
  • Page 33 Graphic FX-50DU-TK(S)-C Units Index Index Accessories General Maintenance ... 5-4 Optional ....1-4 Grounding ....3-3, 4-2 Unit .
  • Page 34 Graphic FX-50DU-TK(S)-C Units Index RS232C Connector ... 3-2 Pin Assignment ... . 2-2 RS422 connector ... . . 3-2 Safety Guidelines .
  • Page 35 Graphic FX-50DU-TK(S)-C Units Index MEMO 6 – 4...
  • Page 36 HARDWARE MANUAL GRAPHIC FX-50DU-TK(S)-C UNITS MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE: MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100 TELEX: J24532 CABLE TOKYO HIMEJI WORKS: 840, CHIYODA CHO, HIMEJI, JAPAN Effective JAN. 1997 Specifications are subject JY992D64301A to change without notice.

This manual is also suitable for:

Melsec-f fx-50du-tk-c

Table of Contents