6.9

Related Devices

List of related devices

Special relays
■FX5 only
Device No.
CH1
CH2
CH3
SM8500
SM8510
SM8520
SM8561
SM8571
SM8581
SM8562
SM8572
SM8582
SM8563
SM8573
SM8583
SM8564
SM8574
SM8584
SM8565
SM8575
SM8585
R: Read only, R/W: Read/Write
■FX3 Series compatible
Device No.
CH1
CH2
SM8063
SM8438
SM8401
SM8421
SM8404
SM8424
SM8405
SM8425
SM8409
SM8429
R: Read only
Special registers
■FX5 only
Device No.
CH1
CH2
CH3
SD8500
SD8510
SD8520
SD8502
SD8512
SD8522
SD8560
SD8570
SD8580
SD8561
SD8571
SD8581
SD8563
SD8573
SD8583
SD8564
SD8574
SD8584
SD8565
SD8575
SD8585
SD8621
SD8631
SD8641
SD8622
SD8632
SD8642
SD8623
SD8633
SD8643
SD8624
SD8634
SD8644
SD8625
SD8635
SD8645
SD8626
SD8636
SD8646
Name
CH4
SM8530
Serial communication error
SM8591
Send request flag
SM8592
Receiving completed flag
SM8593
Carrier detection flag
SM8594
DSR detection flag
SM8595
Time-out flag
Name
Serial communication error
Sending wait flag
Carrier detection flag
DSR detection flag
Time-out flag
Name
CH4
SD8530
Serial communication error
code
SD8532
Serial communication
settings
SD8590
Amount of remaining send
data
SD8591
Amount of data already
received
SD8593
Receive data sum
SD8594
Receiving result sum
SD8595
Sending sum
SD8651
Time-out time
SD8652
8-bit processing mode
SD8653
Header
SD8654
SD8655
Terminator
SD8656
Description
Turns ON when an error occurs in serial communication.
When this device is set to ON, the PLC starts to send.
This device turns ON when receiving is completed.
This device turns ON in synchronization with the CD (DCD) signal.
This device turns ON in synchronization with the DR (DSR) signal.
This device turns ON when data receiving is suspended and the next
set of receive data is not given within the time set by the time-out
time setting device.
Description
Turns ON when an error occurs in serial communication.
This device remains ON while the PLC is waiting to send.
This device turns ON in synchronization with the CD (DCD) signal.
This device turns ON in synchronization with the DR (DSR) signal.
This device turns ON when data receiving is suspended and the next
set of receive data is not given within the time set by the time-out
time setting device.
Description
Stores the error code when a serial communication error occurs.
Stores the setting of the communication parameter.
These devices store the amount of remaining send data.
This device stores the amount of received data.
These devices store the received sum check value.
These devices store the sum check value calculated using the
received data.
These devices store the sum check value added to the send data.
These devices store the time-out time set in the communication
settings.
These devices store the send/receive data processing mode set in
the communication settings.
These devices store the contents of headers 1 to 4 set in the
communication settings.
These devices store the contents of terminators 1 to 4 set in the
communication settings.
6 NON-PROTOCOL COMMUNICATION
R/W
R
R/W
R/W
R
R
R
R/W
R
R
R
R
R
R/W
R
R
R
R
R
R
R
R/W
R/W
R/W
R/W
179
6.9 Related Devices