7
Open the cover [M3].
8
Wipe off the dirt at the paper path of the
registration unit with a hydro-wipe (non-
woven fabric without fluff).
9
Close the cover [M3].
10
Wipe off the dirt at the pre-fusing guide
plate with a hydro-wipe (non-woven
fabric without fluff).
NOTICE
-
Do not use alcohol when you clean the pre-fusing
guide plate.
NOTICE
-
Be careful not to deform the sheet (
entrance of the fusing unit when you clean the pre-
fusing guide plate.
) at the
bizhub PRESS C1100/C1085
1-4