Measure the chart using the instrument.
After you finish the chart measurement,
click [OK].
NOTICE
When the values of Ch and E* are not G7 standard as
the result of the accuracy check, the dialogue is
displayed. You can choose to recalculate and register the
calibration table to fit in the target range or register as is
in the dialogue. Conduct the recalculation.
If you recalculate and the values of Ch and E* are still
not G7 standard, check the following adjustment items.
- Gamma automatic adjustment
- Density balance adjustment
- Maximum Density Auto Adjustment (RU)
- Color density manual control
Tips
The measurement results (Gray Step) are displayed on
[Calibration Manager] screen.
When [Report Print] is clicked, the measurement results
for G7 calibration is printed.