Sample Output For The Firmwaredownload Command - HP AA-RS2WC-TE Installation Manual

Storageworks core switch 2/64
Table of Contents

Advertisement

Figure 38: Sample output for the firmwaredownload command
5. Verify the reboot is complete and the CP cards have achieved failover
6. Enter the version or firmwareshow command to verify the firmware
7. Create a serial connection to the new CP card (instructions provided in
Core Switch 2/64 V4.1 Installation Guide
For more information about the firmwaredownload command, refer
to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide.
SW1:admin> firmwaredownload
Server Name or IP Address: 123.456.78.90
User Name: user
File Name: /v4.0.2/release.plist
Password: xxxxxx
Full Install (Otherwise upgrade only) [Y]:
Do Auto-Commit after Reboot [Y]:
Reboot system after download [N]: y
Start to install packages......
dir ##################################################
terminfo
##################################################
<some output not shown>
glibc ##################################################
sin ##################################################
Write kernel image into flash.
file verification SUCCEEDED
Firmwaredownload completes successfully.
SW1:admin>
redundancy.
a. Wait until the Status LEDs on both CP cards turn off.
b. Enter the hashow command, and verify that the command output
includes HA Enabled Heartbeat Up.
If not, wait a minute and reenter the command, until you have verified
that redundancy is achieved.
version has been updated (see
on page 135).
Installing Core Switch 2/64 FRUs
Figure
38).
step
1,
145