Slotshow; Sensorshow - HP AA-RS2WC-TE Installation Manual

Storageworks core switch 2/64
Table of Contents

Advertisement

slotShow

This command displays info about which slots are occupied, as shown in the
following example.

sensorShow

This command displays the current temperature readings, fan status and RPM,
power supply and fan readings from sensors, as shown in the following example.
This command is per logical switch.
Core Switch 2/64 V4.1 Installation Guide
switch:admin> slotShow
Slot
Blade Type
---------------------------------
1
SW BLADE
2
SW BLADE
3
SW BLADE
4
SW BLADE
5
CP BLADE
6
CP BLADE
7
UNKNOWN
8
SW BLADE
9
SW BLADE
10
UNKNOWN
sw0_155:admin> sensorShow
sensor
1: (Temperature) is Ok, value is 36 C
sensor
2: (Temperature) is Ok, value is 35 C
sensor
3: (Temperature) is Absent
sensor
4: (Temperature) is Absent
sensor
5: (Temperature) is Ok, value is 21 C
sensor
6: (Temperature) is Ok, value is 21 C
sensor
7: (Fan
sensor
8: (Fan
sensor
9: (Fan
sensor 10: (power supply ) is Ok
sensor 11: (power supply ) is Faulty
sensor 12: (power supply ) is Ok
sensor 13: (power supply ) is Faulty
ID
Status
2
FAULTY
2
DISABLED
2
ENABLED
2
DIAG RUNNING POST2
1
ENABLED
1
ENABLED
VACANT
2
DIAG RUNNING POST1
2
INSERTED, NOT POWERED ON
VACANT
) is Ok, speed is 2576 RPM
) is Ok, speed is 2481 RPM
) is Ok, speed is 2463 RPM
Operating the Core Switch 2/64
119

Advertisement

Table of Contents
loading

Table of Contents