Sample Output For The Hashow Command - HP AA-RS2WC-TE Installation Manual

Storageworks core switch 2/64
Table of Contents

Advertisement

Installing Core Switch 2/64 FRUs
3. Enter the hashow command to determine which CP card is active (see
Figure 31: Sample output for the hashow command
Note:
unless otherwise indicated. For more information about commands, refer to the
StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide.
4. If the healthy CP card is performing as the active CP card, continue with
136
Figure
31).
SW0:admin> haShow
Local CP (Slot 5, CP0): Active
Remote CP (Slot 6, CP1): Standby, Healthy
HA enabled, Heartbeat Up
SWO:admin>
Enter all remaining commands from the serial console for the active CP card,
step
7. If the faulty CP card is performing as the active CP card, fail over the
cards (see
Figure
32):
a. Create a serial connection to the faulty CP card (repeat
page 135).
b. Log into the serial console as Admin and enter 0 to log into logical Switch
0.
c. Enter the hafailover command. The healthy CP card becomes the
active CP card.
d. Wait until the Status LED on the healthy CP card is no longer lit
(indicates failover is complete).
e. Enter the hashow command from the serial console for the healthy CP
card to verify the failover.
step
Core Switch 2/64 V4.1 Installation Guide
HP
1, on