No.
Name
Rotation Direction for
T2-19
Auto-Tuning of PG-E3
<44>
Encoder Characteristics
<4> Default setting value varies by the drive model (o2-04).
<9> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive. Multiply value by 2.875 for 600 V class drives.
<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU20008 to 20033, 40005 to 40018, and
50003 to 50013 display values in 0.01 A units, while models CIMR-LU20047 to 20415, 40024 to 40605, and 50017 to 50200
display values in 0.1 A units.
<30> Setting units are determined by the induced voltage constant unit selection for PM motors set to T2-13.
<43> When PG-E3 option connected: Max setting = 48
<44> Available in drive software versions PRG: 7017 or later.
◆ U: Monitors
Monitor parameters allow the user to view drive status, fault information, and other data concerning drive operation.
U1: Operation Status Monitors
■
No.
Name
U1-01
Speed Reference
U1-02
Output Speed
U1-03
Output Current
U1-04
Control Method
U1-05
Speed Feedback
Output Voltage
U1-06
Reference
U1-07
DC Bus Voltage
U1-08
Output Power
U1-09
Torque Reference
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Sets the direction of motor rotation for execution of Auto-Tuning of PG-E3 encoder
characteristics (T2-01 = 12).
0: Forward (Up)
1: Reverse (Down)
Monitors the speed reference.
Displays the output speed.
Displays the output current.
0: V/f Control
2: Open Loop Vector Control
3: Closed Loop Vector Control
7: Closed Loop Vector Control for PM
Displays the motor speed feedback.
Displays the output voltage.
Displays the DC bus voltage.
Displays the output power (this value is calculated internally).
Monitors the internal torque reference.
Description
Description
B Parameter Table
Setting
Default: 0
Min: 0
Max: 1
Analog Output
Unit
Level
10 V: Max
0.01%
frequency
<29>
(-10 to +10 V)
10 V: Max
0.01%
frequency
<29>
(-10 to +10 V)
10 V: Drive
<10> <40>
rated current
No signal output
–
available
10 V: Max
0.01%
Frequency
<29>
(-10 to +10 V)
10 V: 200
0.1 Vac
Vrms
<9>
10 V: 400 V
1 Vdc
<9>
10 V: Drive
rated power
<12>
(kW)
(-10 to +10 V)
10 V: Motor
rated torque
0.1%
(-10 to +10 V)
B