◆ o: Operator Related Parameters

The o parameters set up the digital operator displays.
o1: Digital Operator Display Selection
No.
Name
o1-01
Drive Mode Unit Monitor
Selection
o1-02
User Monitor Selection
after Power Up
Digital Operator Display
o1-03
Unit Selection
o1-04
V/f Pattern Setting Units
o1-05
LCD Contrast Control
o1-06
User Monitor Selection
Mode
<44>
o1-07
Second Line Monitor
Selection
<44>
o1-08
Third Line Monitor
Selection
<44>
User-Set Display Units
o1-10
Maximum Value
User-Set Display Units
o1-11
Decimal Display
o1-12
Length Units
o1-20
Traction Sheave Diameter Sets the traction sheave diameter for display unit calculations.
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Switches the display after the power has been turned on. When using an LED
operator, pressing the up arrow key will display the following data: frequency
reference → rotational direction → output frequency → output current → output
voltage → U1-.
(This is done by entering the 1 part of U1-. Certain monitors are not available
in some control modes.)
o1-02 selects the information that is displayed when the power is turned on.
1: Speed reference (U1-01)
2: Direction
3: Output speed (U1-02)
4: Output current (U1-03)
5: User-selected monitor (set by o1-01)
Sets the units the drive should use to display the frequency reference and motor speed
monitors.
0: 0.01 Hz
1: 0.01% (100% = E1-04)
2: r/min (calculated using the number of motor poles setting in E2-04, E4-04, or
E5-04)
3: User-selected units (set by o1-10 and o1-11)
4: Elevator units 1 (speed in m/s, accel/decel rate and jerk in s)
5: Elevator units 2 (speed in m/s, accel/decel rate in m/s
6: Elevator units 3 (speed in ft/min, accel/decel rate in ft/s
0: Hz
1: r/min
Sets the brightness of the LCD operator (option).
0: 3 Monitor Sequential (Displays the next 2 sequential monitors)
1: 3 Monitor Selectable (o1-07 and o1-08 selected monitor is displayed)
Selects the monitor displayed on the second line.
Selects the monitor displayed on the third line.
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output frequency.
o1-11 sets the position of the decimal position.
0: Millimeter unit
1: Inch unit
Description
2
, jerk in m/s
, jerk in ft/s
2
B Parameter Table
Setting
Default: 106
(Monitor U1-06)
Min: 105
Max: 699
Default: 1
Min: 1
Max: 5
Default: 1
Min: 0
Max: 6
<21>
3
)
)
3
Default:
<5>
Min: 0
Max: 1
Default: 3
Min: 0
Max: 5
Default: 0
Min: 0
Max: 1
Default: 102
Min: 101
Max: 699
Default: 103
Min: 101
Max: 699
Default:
<20>
Min: 1
Max: 60000
Default:
<20>
Min: 0
Max: 3
Default: 0
Min: 0
Max: 1
Default: 400
mm
<38>
Min: 100 mm
Max: 2000
mm
<38>
B