Safe Disable Input Function - YASKAWA L1000A Quick Start Manual

Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

L1-03 Motor Overload Alarm Operation Selection
Setting
0
Ramp to Stop
1
Coast to Stop
2
Fast-Stop
3
Alarm Only (default setting)
L1-04 Motor Overload Fault Operation Selection
Setting
0
Ramp to Stop
1
Coast to Stop (default setting)
2
Fast-Stop

◆ Safe Disable Input Function

This section explains the Safe Disable function and how to use it in an elevator installation. Contact Yaskawa if more
information is required.
Safety Standards
The TUV mark indicates compliance with safety standards.
Figure 100
Standard Models (CIMR-LA)
Table 69 Safety Standards and Applicable Harmonized Standards for CIMR-LA
Safety Standards
Functional Safety
Safety of Machinery
Models in Compliance with IEC/EN 61508 SIL3 (CIMR-LF)
Table 70 Safety Standards and Applicable Harmonized Standards for CIMR-LF
Safety Standards
Functional Safety
Safety of Machinery
The Safe Disable function is in compliance with these standards.
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Figure 109 TUV mark
EMC
EMC
Description
Description
Applicable Harmonized Standards
IEC/EN 61508 series (SIL2)
IEC/EN 61800-5-2 (SIL2)
ISO/EN ISO 13849-1/AC: 2009 (PL d (Cat.3))
EN 61800-3: 2004/A1: 2012
IEC 61800-3: 2004/A1: 2011
Applicable Harmonized Standards
IEC/EN 61508 series: 2010 (SIL3)
IEC/EN 62061: 2005 (SILCL3)
IEC/EN 61800-5-2: 2007 (SIL3)
ISO/EN ISO 13849-1/AC: 2009 (PL e (Cat.3))
IEC/EN 61326-3-1: 2008 (EMC-related)
C Standards Compliance
C
237