◆ E: Motor Parameters

E1: V/f Pattern
No.
Name
E1-01
Input Voltage Setting
E1-03
V/f Pattern Selection
Maximum Output
E1-04
Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
E1-07
Middle Output Frequency
Middle Output Frequency
E1-08
Voltage
Minimum Output
E1-09
Frequency
Minimum Output
E1-10
Frequency Voltage
E1-11
Middle Output Frequency
2
<11>
E1-12
Middle Output Frequency
Voltage 2
<11>
E1-13
Base Voltage
<13>
<2> Default setting is dependent on the control mode (A1-02) and the drive model (o2-04).
<5> Default setting is determined by the control mode (A1-02).
<9> Values shown here are for 200 V class drives. The default is 400 V when using a 400 V class drive. Multiply value by 2.875 for 600 V class
drives.
<11> Parameter is ignored when E1-11 and E1-12 are set to 0.0.
<13> When E1-13 (Base Voltage) is set to 0.0, output voltage is controlled with E1-05 (Maximum Voltage) = E1-13. When Auto-Tuning is
performed, E1-05 and E1-13 are automatically set to the same value.
<23> Setting range depends on the type of motor being used. CLV allows a setting range of 10.0 to 200.0 Hz, while CLV/PM allows a setting range
of 4.0 to 200.0 Hz.
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
This parameter must be set to the power supply voltage.
WARNING! Electrical Shock Hazard. Drive input voltage (not motor voltage) must
be set in E1-01 for the protective features of the drive to function properly. Failure to
do so may result in equipment damage and/or death or personal injury.
F: Custom V/f, E1-04 through E1-13 settings define the V/f pattern
To set linear V/f characteristics, set the same values for E1-07 and E1-09. In this case,
the setting for E1-08 will be disregarded. Ensure that the five frequencies are set
according to these rules:
E1-09 ≤ E1-07 < E1-06 ≤ Ε1−11 ≤ E1-04
Note that if E1-11 = 0, then both E1-11 and E1-12 are disabled, and the above
conditions do not apply.
Output Voltage (V)
E1-05
E1-12
E1-13
E1-08
E1-10
Note: Some parameters may not be available depending on the control mode.
• E1-07, E1-08 and E-10 are available only in the V/f control and Open Loop Vector
control modes.
• E1-11, E1-12 and E-13 are available only in the V/f control and Closed Loop
Vector control modes.
Description
E1-09
E1-07 E1-06 E1-11 E1-04
Frequency (Hz)
B Parameter Table
Setting
Default: 230 V
<9>
Min: 155 V
Max: 255 V
<9>
Default: F
Min: –
Max: F
Default:
<5>
Min:
<23>
Max: 200.0 Hz
Default: 230.0
V
<9>
Min: 0.0 V
Max: 255.0 V
<9>
Default:
<5>
Min: 0.0 Hz
Max: 200.0 Hz
Default: 3.0 Hz
Min: 0.0 Hz
Max: 200.0 Hz
Default:
<2> <9>
Min: 0.0 V
Max: 255.0 V
<9>
Default:
<5>
Min: 0.0 Hz
Max: 200.0 Hz
Default:
<2> <9>
Min: 0.0 V
Max: 255.0 V
<9>
Default: 0.0 Hz
Min: 0.0 Hz
Max: 120.0 Hz
Default: 0.0 V
<9>
Min: 0.0 V
Max: 255.0 V
<9>
Default: 0.0 V
<9>
Min: 0.0 V
Max: 255.0 V
<9>
B
175