◆ S: Elevator Parameters

This section describes various functions and faults needed to operate an elevator application: braking sequence, slip
compensation for elevators, start/stop optimization, Rescue Operation, and elevator-related faults.
S1: Brake Sequence
No.
Name
S1-01
Zero Speed Level at Stop
DC Injection Current at
S1-02
Start
DC Injection Current at
S1-03
Stop
DC Injection/Position
S1-04
Lock Time at Start
DC Injection/Position
S1-05
Lock Time at Stop
S1-06
Brake Release Delay Time
S1-07
Brake Close Delay Time
Run Command Delay
S1-10
Time
Output Contactor Open
S1-11
Delay Time
S1-12
Motor Contactor Control
During Auto-Tuning
<39>
S1-26
Emergency Stop Start
Level
<44>
<5> Default setting is determined by the control mode (A1-02).
<39> Available in drive software versions PRG: 7016 or later.
<44> Available in drive software versions PRG: 7017 or later.
200
Determines the speed to begin applying DC Injection (or Position Lock) when the
drive is ramping to stop (b1-03 = 0). Set as a percentage of the maximum output
frequency (E1-04).
Determines the amount of current to use for DC Injection at start. Set as a percentage
of the drive rated current.
Determines the amount of current to use for DC Injection at stop. Set as a percentage
of the drive rated current.
Determines how long the drive should perform DC Injection at start. In CLV and
CLV/PM, S1-04 determines how long Position Lock should be performed. A setting
of 0.00 disables S1-04.
Determines how long the drive should perform DC Injection at stop. In CLV and
CLV/PM, S1-05 determines how long Position Lock should be performed. A setting
of 0.00 disables S1-05.
Determines the delay time between the start of DC injection/Position Lock and setting
the brake control command (H2- = 50) in order to release the brake at the
beginning of the ride.
Determines the delay time between reaching Zero Speed (S1-01) and resetting the
brake control command (H2- = 50) in order to apply the brake at the end of the
ride.
Sets the time that must pass after the Up/Down command is entered until the drive
internal Run command is set and the ride is started.
Determines the delay time between shutting off the output of the drive and resetting
the contactor control command (H2- = 51) in order to release the motor contactor
after a ride has finished.
Determines the state of the output contactor control command (H2- = 51) during
Auto-Tuning.
0: Disabled
1: Enabled
2: Enabled during Auto-Tuning and HBB
Note: Setting 2 is available in the control mode CLV or CLV/PM for drives with
software versions PRG: 7017 or later. The setting is 0 or 1 for software version PRG:
7016.
Sets the Emergency Stop Start Level as a percentage of the Maximum Output
Frequency.
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Description
Setting
Default:
<5>
Min: 0.000%
Max: 9.999%
Default: 50%
Min: 0%
Max: 100%
Default: 50%
Min: 0%
Max: 100%
Default: 0.40 s
Min: 0.00 s
Max: 10.00 s
Default: 0.60 s
Min: 0.00 s
Max: 10.00 s
Default: 0.20 s
Min: 0.00 s
Max: 10.00 s
Default: 0.10 s
Min: 0.00 s
Max: [S1-05]
Default: 0.10 s
Min: 0.00 s
Max: 1.00 s
Default: 0.10 s
Min: 0.00 s
Max: 1.00 s
Default: 0
Min: 0
Max: 2
Default: 10.0%
Min: 0.0%
Max: 100.0%