APPENDIX

Appendix 2.6 RITO instruction

Internal device
Set data
(System, user)
Bit
n1
n2
(D)
n3
[Instruction
[Execution
symbol]
condition]
RITO
RITO
Device
Un
Start I/O number of the module
Intelligent device station number
n1
Random access buffer specification
The offset value of the automatic update buffer of the intelligent
n2
device station specified by the master station or the random
access buffer.
(D)
Start number of the device to which write data is to be stored.
n3
Number of points to write
1: The value set in the station information settings of the network parameters of the GX Developer.
2: No processing will be performed when set to "0".
App - 26
The RITO instruction writes data to the automatic update buffer of the specified station.
MELSECNET/H
File
register
Word
Bit
Command
Command
Description
Usable devices
Special
Direct J \
function
module
Word
U \G
G.RITO
Un
GP.RITO
Un
Set data
Index
Constant
register
Z
K, H
n1
n2
(D)
n1
n2
(D)
Setting range
0 to FE
H
1 to 64
FF
H
Between 0 and parameter
1
setting value
Within the range of the
specified device
2
0 to 4096
MELSEC-Q
Other
S
n3
n3
Data type
Binary 16 bits
Device
Binary 16 bits
App - 26