8 PROGRAMMING
(Example)
Master station
Remote input (RX)
Address
Station
4000
RX F to RX 0
H
number 1
4001
RX 1F to RX 10
H
4002
RX 2F to RX 20
H
4003
RX 3F to RX 30
H
4004
RX 4F to RX 40
H
4005
RX 5F to RX 50
H
4006
RX 6F to RX 60
H
4007
RX 7F to RX 70
H
Station
number 2
4008
RX 8F to RX 80
H
4009
RX 9F to RX 90
H
400A
RX AF to RX A0
H
400B
RX BF to RX B0
H
400C
RX CF to RX C0
H
400D
RX DF to RX D0
H
400E
RX ED to RX E0
H
to
41FC
RX1FCF to RX1FC0
H
41FD
RX1FDF to RX1FD0
H
41FE
RX1FEF to RX1FE0
H
41FF
RX1FFF to RX1FF0
H
8 - 22
(10) Ver.2 compatible remote input (RX) and Ver.2 compatible remote
output (RY)
Used when the remote net ver. 2 mode or remote net additional mode is
selected.
(a) Master station
1) Master station
The input status from the remote I/O station, remote device station
(RX) and local station (RY) is stored.
When 1 station is occupied, 2, 4 or 8 words are used. The number of
used points changes depending on the expanded cyclic setting and
the number of occupied stations. (see Section 3.1)
2) Local station
Data to be sent to the master station is stored in the remote output
(RY) of the address corresponding to the host station number.
The input status from the remote I/O station, remote device station
(RX) and other local station is stored.
When 1 station is occupied, any of 2 to 8 words are used. The number
of used points changes depending on the expanded cyclic setting and
the number of occupied stations. (see Section 3.1)
... The last two bits cannot be used for communication between the master
station and the local station.
(In the example below, RYEE and RYEF cannot be used.)
(Station number 1: Occupies 1 station,
Remote I/O station point setting:
to
remote I/O station/remote device station/local station
Remote I/O station
16-point setting)
X0F
to
X00
MELSEC-Q
Local station
(Station number 2: Occupies 4 stations,
Expanded cyclic setting: double)
Remote output (RY)
Address
4200
RY F to RY 0
4201
RY 1F to RY 10
4202
RY 2F to RY 20
4203
RY 3F to RY 30
4204
RY 4F to RY 40
4205
RY 5F to RY 50
4206
RY 6F to RY 60
4207
RY 7F to RY 70
4208
RY 8F to RY 80
4209
RY 9F to RY 90
420A
RY AF to RY A0
420B
RY BF to RY B0
420C
RY CF to RY C0
420D
RY DF to RY D0
420E
RY ED to RY E0
to
RY1FCF to RY1FC0
43FC
RY1FDF to RY1FD0
43FD
RY1FEF to RY1FE0
43FE
RY1FFF to RY1FF0
43FF
Station
H
number 1
H
H
H
H
H
H
H
Station
number 2
H
H
H
H
H
H
H
to
H
H
H
H
8 - 22