Mitsubishi MELSEC Q Series User Manual page 382

Cc-link system master/local module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

11 COMMUNICATION BETWEEN THE MASTER STATION AND LOCAL
STATIONS
Item
1 to 7
Retry count
Default: 3
Automatic reconnection
1 to 10
station count
Default: 1
Blank, 1 to 64 (Blank: No standby master station
Standby master station No.
specified)
Default: Blank
Stop/continue
PLC down select
Default: Stop
Asynchronous/synchronous
Scan mode setting
Default: Asynchronous
0 to 100 (0: Not specified)
Delay information setting
Default: 0
11 - 39
Setting range
(b) Example of network parameter settings
An example of network parameter settings is shown below:
MELSEC-Q
Setting value
times
modules
Stop/continue
Asynchronous/synchronous
11 - 39