Error code
Description
959.32
Failure to init physical interface.
Replace the controller board.
959.33
Unknown/unexpected Error.
Replace the controller board.
959.34
System Pensive Bus Busy Error.
Replace the controller board.
959.35
Transmission Error.
Replace the controller board.
959.36
Pensive command is invalid due to unlocked device
status.
Replace the controller board.
959.37
Pensive command is invalid due to locked device
status.
Replace the controller board.
959.38
Incremental counter id(s) are invalid.
Replace the controller board.
959.39
Invalid NV address.
Replace the controller board.
959.40
Invalid Pensive command.
Replace the controller board.
4.6.15 96y error
96y error messages
Error code
Description
960.xx
RAM Memory Error—RAM soldered on the card is
bad.
Replace the controller board.
961.xx
RAM Memory Error—optional DRAM is bad
bizhub 4020/3320 Service Manual
- 142 -
Action
Go to
Controller board
removal.
Go to
Controller board
removal.
Go to
Controller board
removal.
Go to
Controller board
removal.
Go to
Controller board
removal.
Go to
Controller board
removal.
Go to
Controller board
removal.
Go to
Controller board
removal.
Go to
Controller board
removal.
Action
Go to
Controller board
removal.
Go to
RAM memory error service
check.