Horizontal Sliding Contact Connector - Konica Minolta bizhub 4020 Service Manual

Hide thumbs Also See for bizhub 4020:
Table of Contents

Advertisement

2. Insert the cable with the contacts on the cable away from the locking actuator. Insert the cable on
top of the actuator.
Note: Verify that the cable is installed squarely into the connector. If the cable is not squarely
installed, then intermittent failures could occur.
3. Rotate the locking actuator to the locked position by pressing down on both ends of the actuator.
The cable should not move when this step is performed. If the cable moves, open the actuator,
reposition the cable, and then close the actuator to the down position.

Horizontal sliding contact connector

This FRU contains a horizontal sliding contact connector. Read the instructions before proceeding.
The horizontal sliding contact connector uses a slide locking actuator to lock the ribbon cable into the
Zero Insertion Force (ZIF) connector. The cable is inserted horizontally into the connector.
bizhub 4020/3320 Service Manual
- 242 -