Errors - Konica Minolta bizhub 4020 Service Manual

Hide thumbs Also See for bizhub 4020:
Table of Contents

Advertisement

4.6.3

132 errors

132 error messages
Error code
Description
132.01
TDS baseline too low.
132.02
TDS baseline too high.
132.03
TDS baseline excessive range.
132.16
TDS calibration at maximum.
132.17
TDS calibration too low.
132.18
TDS calibration too close to baseline.
132.32
PC drum measurement too high.
132.33
PC drum measurement too different from
calibration.
132.34
PC drum measurement too close to baseline.
Toner density sensor service check
Action
Step 1
Remove the transfer roll, and then check for loose toner
blocking the toner density sensor.
Is it free of loose toner?
Step 2
Check the TDS for proper operation:
1.
Lower the ACM assembly.
2.
Move the toner density sensor wiper from left to right.
Does it move freely?
Step 3
Check the cable JTDS for proper connection.
Is it properly connected?
bizhub 4020/3320 Service Manual
Yes
Go to step 2.
Go to step 3.
Go to step 4.
- 123 -
Action
Go to
Toner density sensor service
Go to
Toner density sensor service
Go to
Toner density sensor service
Go to
Toner density sensor service
Go to
Toner density sensor service
Go to
Toner density sensor service
Go to
Toner density sensor service
Go to
Toner density sensor service
Go to
Toner density sensor service
No
Clean the sensor.
Reinstall the wiper
properly. If it still cannot
move freely, then
replace the toner density
sensor. See
density sensor
Reseat the cable.
check.
check.
check.
check.
check.
check.
check.
check.
check.
Toner