Pulse Analyze 1; Speedpps(Min/Max); Break; Pulse Analyze 2 - AMERITECH AM8a Instruction Manual

Pcm/vf call analyzer
Table of Contents

Advertisement

Analysis Parameters

4.6 PULSE ANALYZE 1

This is the first of two menus used for PULSE dial analysis. This menu contains parameters
for the speed and percent of break time analysis.
PULSE
ANALYZE 1:
Alternate:
NOTE: The OFF HOOK vdc parameter described in 4.11.2 will also affect the
ability to detect PULSE dial digits.
4.6.1 SPEEDpps(min/max): When pulse dialing is received, the SPEED (pulses per second)
must fall within the min and max range programmed here. If the SPEED falls outside
this range, the Event is flagged as an error.
4.6.2 BREAK%: When pulse dialing is received, the BREAK % must fall within the min and
max range programmed here. If the % BREAK falls outside this range, the Event is
flagged as an error.

4.7 PULSE ANALYZE 2

This is the second of two menus used for PULSE dial analysis. This menu contains parameters
for the interdigit time analysis.
PULSE
ANALYZE 2:
Alternate:
4.7.1 INTERDIGITms(min): When PULSE dialing is received, the INTERDIGIT time must fall
within this parameter. If the time falls outside this range, the Event is flagged as an
error.
February 10, 2000
(18-0037)
:

SPEEDpps(min/max)

8.0
12.0
5 to 25 (0.1pps steps)
:
INTRDIGITms(min)
120 to 999 (1ms steps)
4-4
AM8a Instruction Manual

BREAK%

50
70
20 to 85 (1% steps)
300
0037-S04.L_

Advertisement

Table of Contents
loading