AMERITECH AM8a Instruction Manual page 118

Pcm/vf call analyzer
Table of Contents

Advertisement

AM8a Instruction Manual
Cadence:
Rings:
On Time:
Off Time:
Ring time (before thermal shutdown)
Minimum:
Typical:
Call Progress Tones
Dial Tone Generation:
Low Frequency:
Low Frequency Level:
High Frequency:
High Frequency Level:
Cadence:
Tone Burst:
On Time:
Off Time:
Start Signals
Wink
Begin:
Duration:
Delay
Begin:
End:
Dial Tone Delay
from Seizure:
Dialing
Pulse
Speed:
Percent Break:
Interdigit Time:
Accuracy at 10 pps:
SF
Frequency:
Level:
Speed:
Percent Break:
Interdigit Time:
Accuracy at 10 pps:
0037-S08.L_48
(18-0037)
1 to 3, individual on/off timers
0 to 5000 ms
0 to 9999 ms
5 minutes (max load)
10 minutes
0, or 300 Hz to 3300 Hz
–40 dBm to –3 dBm
0, or 300 Hz to 3300 Hz
–40 dBm to –3 dBm
1 to 3, individual on/off timers
0 to 9999 ms
0 to 9999 ms
15 to 999 ms
50 to 999 ms
15 to 999 ms
100 to 9999 ms
15 to 9999 ms
5 to 25 pps
40% to 85%
120 to 999 ms±3ms
±0.1 pps (40% to 75% break ±1%)
2600 Hz
–30dBm to 0 dBm
8 to 16 pps
40% to 85%
120 to 999 ms ±2ms
±0.1 pps (40% to 85% break ±1%)
8-3
Technical Specifications
February 10, 2000