Dialing Emulate; Loop Type; Start Signal; Pulse Emulate - AMERITECH AM8a Instruction Manual

Pcm/vf call analyzer
Table of Contents

Advertisement

Emulation Parameters
3.2.2 DC HOLD: This parameter controls the DC holding resistance placed across Tip and
Ring during an OFF-HOOK condition.

3.3 DIALING EMULATE

This menu controls the dialing type and the signal used as a start dial indication.
DIALING :
EMULATE:
Alternate:
3.3.1 LOOP TYPE: This selects the dialing type the AM8a will out-pulse. This dialing type
may be changed using the "TOGGLE DIAL" key (or equivalent character in an AUTO
DIAL sequence).
3.3.2 START SIGNAL: This is the START SIGNAL provided by the AM8a when the START key
is pressed or the AM8a is in the AUTO mode and an OFF HOOK is detected.

3.4 PULSE EMULATE

The PULSE dialing specifications are programmed in this menu. These parameters are used
when the AM8a LOOP TYPE parameter is set to PULSE in the DIALING menu.
PULSE
:
EMULATE:
Alternate:
3.4.1 SPEEDpps: This controls the number of pulses per second for each digit out-pulsed.
3.4.2 BREAK%: This controls the % of break (open loop) of each pulse making up a out-
pulsed digit.
3.4.3 INTRDIGITms: The Inter-Digit Time is programmed here. This is the amount of time
from the last pulse of the previous digit until the first pulse of the next digit.
February 10, 2000
(18-0037)

LOOP TYPE

pulse
dtmf
mf(R1)
SPEEDpps

BREAK%

10
60
5 to 25
40 to 85
3-2
AM8a Instruction Manual

START SIGNAL

wink
Immediate
delay
dial tone

INTRDIGITms

600
120 to 999
0037-S03.L_

Advertisement

Table of Contents
loading

Table of Contents