Start Time Emulate; Dly:bgn/Endms; Wink:bgn/Durms; Sf Emulate - AMERITECH AM8a Instruction Manual

Pcm/vf call analyzer
Table of Contents

Advertisement

AM8a Instruction Manual

3.13 START TIME EMULATE

These parameters are used for programming the timing of the DELAY and WINK START
SIGNALS.
START TIME:
EMULATE :
Alternate:
BGN = 15 to 999 (1ms steps)
END = 100 to 9999 (1ms steps)
3.13.1 DLY:BGN/ENDms: This setting controls the DeLaY BeGiN timing. This is the time from
seizure until the DELAY START DIAL signal is sent. The AM8a must be set to
EMULATE and have the AUTOMATIC selection made. The END time is when the DeLaY
signal will be removed.
3.13.2 WINK:BGN/DURms: This setting controls the wink BeGiN timing. This is the time
from seizure until the WINK is sent. The AM8a must be set to EMULATE and have the
AUTOMATIC selection made. The DURation controls how long the wink is on the line.

3.14 SF EMULATE

This menu sets the level and frequency variation of the Single-Frequency (2600Hz) signal that
is used for signaling when the TRUNK TYPE is SF (Refer to 2.4.1).
:
SF
EMULATE :
Alternate:
3.14.1 LEVEL: sets the 2600Hz SF tone from –40 dBm to 0 dBm.
3.14.2 FREQ+%hz: sets the frequency variation of the 2600Hz SF tone from –2% to +2% in
.1 % steps (2548Hz through 2652Hz).
0037-S03.L_24
(18-0037)

DLY:BGN/ENDms

WINK:BGN/DURms

100 250
LEVELdBm
–10
–40 to 0
(1 dBm steps)
3-7
Emulation Parameters
100 250
BGN = 15 to 999 (1ms steps)
DUR = 50 to 999 (1ms steps)
FREQ + %hz
0.0
-2 to 2
(.1 % steps)
February 10, 2000

Advertisement

Table of Contents
loading

Table of Contents