Printouts; Off; All Calls, Events Only; Figure 7-1. Event-Only Printout - AMERITECH AM8a Instruction Manual

Pcm/vf call analyzer
Table of Contents

Advertisement

RS232 Entries and Printouts

Table 7-13. RS232 Meter Display Commands (Noise Measurements)

COMMAND
(MN0) or
Select Noise measurement display
(MN1)
NOISE -65 dBrn
INPUT
(MN0)
(MN0 = 00) for Select Noise measurement INPUT TX.
(MN0 = 01) for Select Noise measurement INPUT RX.
(MN1)
(MN1 = 00) for Select Noise measurement FILTER CMSG.
(MN1 = 01) for Select Noise measurement FILTER FLAT.

7.2 PRINTOUTS

A variety of printouts are available from the AM8a. The printouts may be manual or
automatic. The MANUAL printouts are controlled by the PRINT key on the front panel or the
RS232 Printing Commands shown in Table 7-2.
The automatic printing selections are provided in the PRINT CONFIG menu AUTOPRINT
parameter. (Refer to 2.7 for description of this menu). The following sub-sections provide
information on the print formats.
NOTE: Automatic printouts begin at the end of the start of the next call sequence.
7.2.1 off: No automatic printout will occur. Operator may use the [SHIFT] and [PRINT] keys
for short or long print, or can use equivalent RS232 commands (PET) or (PEB) when
printouts are required.
7.2.2 all calls,events only: The EVENT only printout will show the first line of the Events
Display. This printout can have the same maximum length as the Events Display (80
characters). Figure 7-1 is a sample of an EVENT only printout. (This is also the
printout that would result from a manual short printout while in EVENTS DISPLAY
mode.)
NOTE: Any underlined characters indicate the Event originated from the switch.
Refer to Section 1 for the explanation of the event codes.
February 10, 2000
(18-0037)
DEFINITION
| | | | | | | . . . . . . . . . . . . .
TX
FILTER
>HX1x2765432654325h

Figure 7-1. Event-only Printout

7-16
AM8a Instruction Manual
CMSG
0037-S07.L_