Ringing Emulate 1; On/Offms; Ringing Emulate 2 - AMERITECH AM8a Instruction Manual

Pcm/vf call analyzer
Table of Contents

Advertisement

Emulation Parameters

3.11 RINGING EMULATE 1

This menu controls the ringing Cadence applied to the line during ring.
RINGING
EMULATE 1:
Alternate:
3.11.1 ON/OFFms: Two additional parameters may be used for custom ring cadence
programming. They allow for programming a sequence of cadences to simulate
custom calling features such as callback queuing or auto call back.
NOTE: If Ringing ON time plus OFF time exceeds 10 seconds, a New Call Reset
will occur.

3.12 RINGING EMULATE 2

RINGING
EMULATE 2:
Alternate:
3.12.1 VOLTAGEvrms: This parameter controls the RMS voltage that is applied during the
ring cycle.
3.12.2 FREQUENCYhz: This parameter controls the frequency of the ringing applied during
the ring cycle.
February 10, 2000
(18-0037)

ON/OFFms

ON/OFFms
:
2000 4000
0
on = 0 to 5000 (1ms steps)
off = 0 to 9999 (1ms steps)
:
VOLTAGEvrms
85
30 to 105 (5v steps)
3-6
AM8a Instruction Manual
ON/OFFms
0
0
0
FREQUENCYhz
20.0
15 to 70 (0.1hz steps)
0037-S03.L_