Dly Strt (Delay Start) Analyze; Strt Bgnms(Min/Max); Endms(Min); Wink Strt - AMERITECH AM8a Instruction Manual

Pcm/vf call analyzer
Table of Contents

Advertisement

AM8a Instruction Manual

4.4 DLY STRT (DELAY START) ANALYZE

When the EXPECTED TYPE of Start Signal is set to dialtone/delay, these parameters control
what is reported as an exception. If dialtone is received, these settings are not used.
DLY STRT:

STRT BGNms(min/max)

ANALYZE:
Alternate:
4.4.1 STRT BGNms(min/max): This is the time from off hook to the DELAY dial START
SIGNAL. If the timing is outside the range, it is flagged as an exception.
4.4.2 ENDms(min): This time must be exceeded in order for the delay signal to be valid. A
delay signal shorter than this time will be flagged as an exception.

4.5 WINK STRT

When the EXPECTED TYPE of Start Signal is set to dialtone/wink, these parameters control
what is reported as an exception. If dialtone is received, these settings are not used.
WINK STRT:
ANALYZE :
Alternate:
4.5.1 WINK BGNms(min): This is the time from off hook to the WINK START SIGNAL. If the
timing exceeds this parameter, it is flagged as an exception.
4.5.2 DURms(min/max): This is the time the wink signal must be present to be valid. A wink
signal less than the minimum (min) time or greater than the maximum (max) time of
this setting will be reported as an exception.
0037-S04.L_32
(18-0037)
0
300
0 to 999 (1ms steps)

WINK BGNms(min)

15
15 to 999 (1ms steps)
4-3
Analysis Parameters

ENDms(min)

140
0 to 9999 (1ms steps)

DURms(min/max)

140 290
50 to 999 (1ms steps)
February 10, 2000