3. EMULATE PARAMETERS

The EMULATE parameters are used to define the values and timing of the events initiated by
the AM8a. These parameters are only used when the Te/Line or Switch is set to CONFIG
"MODE emulate". When set to "MODE monitor" they are not used, and also cannot be printed at
a terminal.

3.1 LOOP EMULATE

This menu is used to setup the characteristics of the interface when configured as an analog
LOOP START TRUNK TYPE.
LOOP
:
Alternate:
3.1.1 VOLTAGE: This is the battery voltage that will be supplied by the AM8a when
configured to emulate an analog switch (refer to 2.1 and 2.2).
3.1.2 LENGTH: This parameter allows the selection of the loop length to be simulated by the
AM8a.

3.2 TERMINATION EMULATE

This menu controls the termination for the analog signals on the trunk.
TERMINATION:
EMULATE
Alternate:
3.2.1 2.16uf: 2.16 microfarads is a standard capacitive component of the termination
impedance when set to IN.
out: the capacitance is increased to 24uf so that it has little or no effect on the
termination for audio frequencies from 200Hz to 3400 Hz.
0037-S03.L_24
(18-0037)
VOLTAGEvdc
48
20 to 72
0 to 2100(300ohm steps)
2.16uf
:
in
out
3-1
Emulation Parameters
LENGTHohm
1200

DC HOLD

330ohm
10ohm
430ohm