Configuration Parameters; Mode Config; Imitate; Mode - AMERITECH AM8a Instruction Manual

Pcm/vf call analyzer
Table of Contents

Advertisement

AM8a Instruction Manual

2. CONFIGURATION PARAMETERS

The following displays show in sequence the types of configuration parameters used to
program the AM8a. To use these menus press the CONFIG'N key.
2.1

MODE CONFIG

MODE :

CONFIG:
Alternate:
2.1.1 IMITATE: The AM8a can operate as either terminal/line equipment or as switching
(CO) equipment.
te/line: The AM8a will perform the functions associated with the terminal or line
equipment of the circuit under test. (i.e. seizure, dial out, ring trip, etc.)
switch: The AM8a will provide the functions associated with the switching equipment
of the circuit under test. (i.e. battery, start dial signal, ringing, etc.)
2.1.2 MODE: The MODE selects whether the AM8a will emulate or monitor the equipment as
selected by the IMITATE parameter.
monitor: The AM8a is non-intrusive to the circuit. Events will be displayed as they
occur and the statistics will be recorded for analysis. Call progress tones and dialing
will be displayed as they appear.
emulate: The AM8a will provide the signaling IMITATE mode selected. The signals
provided are specified by the parameters in the EMULATE menus.
NOTE: Emulate cannot be used with SLC®96 I or SLC®96 II INPUT (see 2.3.1).
0037-S02.L_22
(18-0037)

IMITATE

switch
te/line
2-1
Configuration Parameters
MODE
monitor
emulate
February 10, 2000