Yamaha VT700F Service Manual page 442

Hide thumbs Also See for VT700F:
Table of Contents

Advertisement

TROUBLESHOOTING
1. Connect:
Pocket tester
(to the battery terminals)
2. Measure:
Battery voltage
Fluid gravity
Battery voltage:
more than 12 V at 20°C (68°F)
3. Start the engine and accelerate to 5,000
r/min.
4. Measure:
Charging voltage
Charging voltage:
14 V/5,000 r/min
WARNING
Be sure the V-belt is removed.
CAUTION:
Never disconnect battery cables while generator
is operating, otherwise, the rectifier/regulator will
be damaged.
Correct connector.
CHARGING SYSTEM (VX700DX/VT700)
BATTERY IS NOT CHARGED.
OK
SCH8160
OK
8-17
OUT OF SPECIFICATIONS
Check the battery.
Refer to "BATTERY INSPECTION" in CHAPTER 2.
Replace and/or charge the battery.
Refer to "BATTERY CHARGING" in CHAPTER 2.
OUT OF SPECIFICATION
Check the main fuse.
Refer to "FUSE INSPECTION" in CHAPTER 2.
Check the startor coil.
OK
Replace the main fuse, rectifier/regulator
and/or the startor coil assembly.
Replace the rectifier/regulator.
+
ELEC
FAULTY

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sx700fVx700fMm700fVx700dxf

Table of Contents