BATTERY INSPECTION (VX700DX/VT700)
SCH2780
SCH2785
Replace the battery if:
Battery voltage will not rise to a specific value or
bubbles fail to rise even after many hours of
charging.
Sulfation of one or more cells occurs, as indicated
by the plates turning white, or an accumulation of
material exists in the bottom of the cell.
Specific gravity readings after a long, slow charge
indicate one cell to be lower than the rest.
Warpage or buckling of plates or insulators is
evident.
CAUTION:
Always charge a new battery before using it to
ensure maximum performance.
4. Inspect:
Battery terminal
Dirty terminal → Clean with a wire brush.
Poor connection → Correct.
NOTE:
After cleaning the terminals, apply grease lightly to
the terminals.
5. Install:
Battery
CAUTION:
Connect the positive lead to the battery termi-
nal first.
Make sure the battery leads are connected
properly. Reversing the leads can seriously
damage the electrical system.
Make sure that the battery breather hose is
properly connected and is not obstructed.