Omron I537-E2-01 User Manual page 250

Table of Contents

Advertisement

Type
Special Mounted
Fan Unit
Options
Scaling Meter
Analog Operator (stan-
Separately
dard with steel panels)
Installed Options
Analog Operator (small,
plastic)
Braking Unit
Braking Resistor Unit
DC Reactor
Special Options
Digital Operator with
LCD Display
Digital Operator with
LED Display
Digital Operator Connec-
tion Cable
Personal Computer cable
DeviceNet Communica-
Option cards
tions Card
Standard terminal card
7HUPLQDO FDUGV
Optional terminal card
AC Reactor
Simple Input Noise Filter
Input Noise Filter
Recommended
(Schaffner)
Separately
Installed
Input Noise Filter
*1
Options
(Schaffner) for EMC
Directive
Input Noise Filter
(Rasmi) for EMC Direc-
tive
Output Noise Filter
(Tokin)
* 1. Recommended Options can be ordered from OMRON using the above model numbers.
-8
9
Table 9.1 Options and Peripheral Devices
Name
Model number
V
3G3IV-PFAN
V
K3TJ-V11
V
3G3IV-PJVOP96
V
3G3IV-PJVOP95
V
3G3IV-PCDBR
B
V
3G3IV-PLKEB
V
3G3HV-PUZDAB
3G3IV-PJVOP160
3G3IV-PJVOP161
3G3IV-PCN126 (1 m)
3G3IV-PCN326-E (3 m)
3G3IV-PCN329-E
3G3FV-PDRT1-SIN
3G3PV-PETC618140
3G3PV-PETC618120
V
3G3IV-PUZBAB
V
3G3EV-PLNFD
V
3G3IV-PFN
V
3G3RV-PFI
-SE
V
3G3RV-PFI
-E
V
3G3IV-PLF
Application
Replacement fan for Inverters equipped with a cooling fan.
Replace the Cooling Fan when the fan replacement time has come or a cooling fan fault
(FAN) alarm has been displayed.
Connects to a multi-function analog output from the Inverter.
Used to display rotational speeds of motors, line speeds, etc., in physical units.
Allows frequency reference settings and ON/OFF operation control to be performed by
analog references from a remote location (50 m max.).
Frequency counter specifications: 75 Hz, 150 Hz, 220 Hz
Allows frequency reference settings and ON/OFF operation control to be performed by
analog references from a remote location (50 m max.).
Frequency counter specifications: 60/120 Hz, 90/180Hz
Used with a Braking Resistor Unit to reduce the deceleration time of the motor.
Not required with Inverters of 7.5 kW or less for 200-V class Inverters or for Inverters of
15 kW or less for 400-V class Inverters.
Consumes the regenerative motor energy with a resistor to reduce deceleration time (use
rate: 10% ED).
Used to control harmonics generated by the Inverter and to improve the input power fac-
tor of the Inverter. All Inverters of 18.5 kW or higher contain built-in DC reactors.
Displays messages on a LCD.
Display messages on a LED display. Standard in Asia and Europe.
Extension cable to use a 3G3PV-series Digital Operator remotely.
Cable length: 1 m or 3 m
Connection cable for connecting the 3G3PV series Inverter to the SYSDrive configura-
tor (software tool) on Personal Computer.
Used for DeviceNet communications with a Programmable Controller or other
DeviceNet master device.
Standard terminal card for standard operation
Optional terminal card (with shunt connector CN15) for switching the analog output
levels between (0-10V) or (4 to 20 mA).
Used to control harmonics generated by the Inverter or when the power supply capacity
is greatly larger than the Inverter's capacity. Also used to increase the power factor.
Reduces noise coming into the inverter from the power supply line and to reduce noise
flowing from the inverter into the power supply line. Connected to the power supply
input side.
Reduces noise coming into the inverter from the power supply line and to reduce noise
flowing from the inverter into the power supply line.Connected to the power supply
input side.
Required for the 3G3PV Inverter to meet the EMC Directive.
Required for the 3G3PV Inverter to meet the EMC Directive.
Controls noise generated by the Inverter so it does not enter the power supply. Con-
nected to the motor output side.

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents