Keypad / Touchpad Options; Mapping F-64Tp Doors And Pir's - NAPCO FREEDOM F-64 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for FREEDOM F-64:
Table of Contents

Advertisement

WI1502A 9/06
K EYPAD/TOUCH PAD OPTI ON S (ADDRESS 1425-1431, 1440-1446)
KEYPAD OPTI ON S (ADDRESS 0723-0736 & 1055-1058)
Enable Keypad/Touchpad
Type & Activation
Keypad/Touchpad 1
Keypad/Touchpad 2
Keypad/Touchpad 3
Keypad/Touchpad 4
Keypad/Touchpad 5
Keypad/Touchpad 6
Keypad/Touchpad 7
[Default = 1 for address 1425; blank (•) from address 1426-1431]
Enable Keypad Options
Keypad 1 Options
Keypad 2 Options
Keypad 3 Options
Keypad 4 Options
Keypad 5 Options
Keypad 6 Options
Keypad 7 Options
[Default = blank (•) from address 1440-1446, except where specified in table above] * NOTE: Keypad Aux. is not to be selected for UL Installations.
ENABLE KEYPAD OPTIONS: Select options for any of the 7 keypads.
1.
Select the desired option entering the option number (1-8) for each digit.
2.
At the F-64PROG programmer, enter corresponding option number in address location. NOTE: Dark shaded data value
box shows option not available. Press
MAPPIN G F -64T P DOOR S AND P IR'S (ADDRESS 2090-2101)
Keypad address programming locations for mapping F-
64TP Doors and PIR's to the F-64 control panel are dis-
played in the table at right:
In addition, in order for the F-64TP to function correctly
on the F-64 panel, the following programming / installa-
tion rules are required:
1. A F-64TP must be wired and addressed as Key-
pad #1 for any F-64 Touchpads to work on the
system.
2. Must program (map) at least 1 Door Zone and a
PIR for each F-64 Touchpad.
3. All PIR's in the system, including the mapped Inte-
gral F-64 Touchpad PIR, must be programmed as
interior to allow conversion from arming Stay to
Away.
4. All zones programmed for interior must also be
programmed for Auto Bypass.
5. Exit Delay time must first be programmed to allow conversion from arming Stay to Away.
1. Select the desired zone by entering the zone number (001-064) for each address.
2. At the F-64PROG Programmer, enter corresponding zone number in address location. Press
L
NAPCO Security Systems
ENABLE TYPE
Blank (•) = Burg Keypad
ADDR
2 = Wizard *
*Not for UL Installations
1425
1426
1427
1428
1429
1430
1431
Keypad
Keypad
ADDR
Fire
1
1440
ON
1441
ON
1442
ON
1443
ON
1444
1445
1446
U
to save.
AREA ASSIGNMENT
Blank (•) = Disabled
1 = Area 1, 2 = Area 2,
3 = Area 3, 4 = Area 4
1
Enable Keypad Options
Keypad
RSRVD
Aux.*
Panic
2
3
4
ON
ON
ON
ON
Enable Keypad Options

MAPPING F-64TP Doors and PIR's

Zone # of F64TP # 1 Door/Bolt TX #1
Zone # of F64TP # 1 Door/Bolt TX #2
Zone # of F64TP # 1 PIR
Zone # of F64TP # 2 Door/Bolt TX #1
Zone # of F64TP # 2 Door/Bolt TX #2
Zone # of F64TP # 2 PIR \
Zone # of F64TP # 3 Door/Bolt TX #1
Zone # of F64TP # 3 Door/Bolt TX #2
Zone # of F64TP # 3 PIR
Zone # of F64TP # 4 Door/Bolt TX #1
Zone # of F64TP # 4 Door/Bolt TX #2
Zone # of F64TP # 4 PIR
[Default = blank (•) from address 2090-2101]
Freedom F-64 Programming Instructions
Page 29
ENABLE TYPE:
pads/Touchpads may be pro-
grammed, if they are connected.
NOTE: See Touchpad Configu-
ration Mode (see page 40).
1. Select keypad/Touchpad type
for each keypad from the
tables shown.
2. Enter data in corresponding
address locations.
U
3. Press
to save.
Easy
Panel
Ambush
Arming
Access
5
6
7
ON
ON
ON
ON
ADDR
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
U
to save.
Up to 7 key-
RSRVD
8
Zone #
(1-64)
9
10
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-64prog

Table of Contents