2.9 [2] System
Feature Manual References
1.3.1 Caller ID
Channel Seizure Wait Time
Specifies the length of time that the PBX waits before starting to send the seizure signal following the
first ring when sending Caller ID information to an SLT.
Default
512 ms
Value Range
64 × n (n=5–35) ms
Maintenance Console Location
2.9.18 [2-10] Extension CID Settings
Programming Manual References
None
Feature Manual References
1.3.1 Caller ID
Caller ID Signal Type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Specifies the type of signal modulation to be used when sending Caller ID information to an SLT
(reference only).
Default
FSK
Value Range
FSK
Maintenance Console Location
2.9.18 [2-10] Extension CID Settings
Programming Manual References
None
Feature Manual References
1.3.1 Caller ID
Additional Local Trunk Access Code to Extension Caller ID
Enables the PBX to automatically add a CO Line Access number to the received telephone number
when sending the Caller ID number of an incoming CO line call to an SLT.