2.9 [2] System
DISA—No Dial Intercept Timer
Specifies the length of time after the OGM finishes playing in which the caller must begin dialing
before the call is redirected to the operator.
Default
10 s
Value Range
0–120 s
Maintenance Console Location
2.9.4 [2-3] Timers & Counters
Programming Manual References
2.9.3 [2-2] Operator & BGM
2.12.4 [5-3-2] Voice Message—DISA Message
2.13.6 [6-6] Tenant—Operator (Extension Number)
Feature Manual References
1.4.7 DISA (Direct Inward System Access)
DISA—2nd Dial Timer for AA
Specifies the length of time in which the caller must dial the second digit before the DISA AA Service
activates.
Default
2 s
Value Range
0–5 s
Maintenance Console Location
2.9.4 [2-3] Timers & Counters
Programming Manual References
2.12.4 [5-3-2] Voice Message—DISA Message
Feature Manual References
1.4.7 DISA (Direct Inward System Access)
DISA—Intercept Timer—Day, Lunch, Break, Night
Specifies the length of time until an unanswered DISA call is intercepted and redirected to the
intercept routing destination after the original destination receives the call in each time mode.