Value Range
0–600 × 100 ms
Maintenance Console Location
2.8.13 [1-1] Slot—Card Property - PRI type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
ISDN CO / QSIG Master / QSIG Slave—T309
Specifies the length of time that the PBX tries to disconnect the data link, before disconnecting the
call.
Default
120 × 100 ms
Value Range
0–3000 × 100 ms
Maintenance Console Location
2.8.13 [1-1] Slot—Card Property - PRI type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
ISDN CO / QSIG Master / QSIG Slave—T310
Specifies the maximum time that the PBX waits for a continuance message after receiving the
Incoming Call Proceeding message.
Default
1100 × 100 ms
Value Range
0–3000 × 100 ms
Maintenance Console Location
2.8.13 [1-1] Slot—Card Property - PRI type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
2.8 [1] Configuration
PC Programming Manual