2.8 [1] Configuration
Feature Manual References
None
First Dial Timer (DID/TIE)
Specifies the minimum time that the PBX waits after seizing a DID or TIE line, before sending the
dialed digits to the telephone company or to another PBX. This allows the telephone company or the
other PBX to have enough time to accept the dialed digits correctly.
Default
64 ms
Value Range
32 × n (n=1–255) ms
Maintenance Console Location
2.8.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Answer Detection Timer
Specifies the length of time required by the PBX to recognize the answer signal. This allows the
telephone company to have enough time to accept the dialed digits correctly.
Default
32 ms
Value Range
32 × n (n=1–255) ms
Maintenance Console Location
2.8.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Wink Signal Width
Specifies the length of a wink signal.
162