Flash—Flash Signal Detection (OPX)
Enables the PBX to detect hookswitch flash signals from an SLT connected to an OPX.
Default
Enable
Value Range
Disable, Enable
Maintenance Console Location
2.8.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Flash—Minimum BREAK Width (OPX)
Specifies the minimum length of the break signal in a flash signal from an SLT connected to an OPX.
Default
200 ms
Value Range
8 × n (n=3–63) ms
Maintenance Console Location
2.8.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Flash—Flash Width (OPX)
Specifies the maximum length of a flash signal sent from an SLT connected to an OPX that the PBX
can recognize as a hookswitch flash signal.
Default
800 ms
Value Range
8 × n (n=3–191) ms
2.8 [1] Configuration