3. Remove two motor nuts to separate motor.
4. Loosen screw to slide off small pulley from
motor shaft.
5. When reassembling, be sure to adjust belt ten-
sion before tightening motor nuts . Proper adjust-
ment is made when belt can be depressed 1/8 inch
at a point halfway between pulleys.
PRESSURE SWITCH (TYPE 1
WATER PUMP) (FIGURE 22)
The pressure switch, mounted on the type 1 wa-
ter pump, is non-adjustable . If the switch fails to
operate properly, replace it . The pump should oper-
ate between 15 psi and 30 psi.
NOTE:
If the pump is equipped with an earlier
adjustable pressure switch, it should be replaced
when it fails or falls out of adjustment . For
pump models - 1000 and above no conversion kit
is necessary. Pumps below - 1000 require a ser-
vice conversion kit.
Figure 21-Inspecting Dampener
LIVING AREA WATER SYSTEM
24J- 13
Figure 22-Water Pump With Pressure Switch