PERFORMANCE DATA
has a direct relationship to nozzle outlet temper-
ature. If pressure is too low, ice will gradually
The following Performance Data define normal
form on the evaporator fins, restricting air flow
operation of the system under the above conditions .
REFRIGERANT CHARGE - 3.5 LBS.
ENGINE RPM - 2000 RPM
HEAD PRESSURE (EVAP. "IN" CHARGE PORT)*
SUCTION PRESSURE
(EVAPORATOR "OUT" CHARGE PORT)*
DISCHARGE AIR TEMP . A T RIGHT UPPER OUTLET*
*Just prior to compressor clutch disengagement.
Temp. of Air
Entering Condensor
70°F
80°F
90°F
100°F
110°F
Relative Humidity
(21 .1°C)
(26 .7°C)
(32 .2°C)
(37 .8°C)
(43 .3°C)
230-
270-
30%
245
285
190-
237-
283-
40%
205
252
298
157 -
202 -
242 -
60%
172
217
257
127-
167-
210-
80%
142
182
225
Temp. of Air
Entering Condensor
70°F
80°F
90°F
100°F
110°F
Relative Humidity
(21 .1°C)
(26.7°C)
(32.2°C)
(37 .8°C)
(43 .3°C)
14.0-
18 .0-
30%
29.0
33 .0
11 .0-
15 .5-
20 .5-
40%
26.0
30 .5
35 .5
9.5-
13.8-
19 .0-
60%
24 .5
28.8
34.0
6 .5-
11 .0
16 .2-
80%
21 .5
26.0
31 .2
Temp . of Air
Entering Condensor
70°F
80°F
90°F
100°F
110°F
Relative Humidity
(21 .1°C)
(26 .7°C)
(32 .2°C)
(37 .8°C)
(43.3°C)
60-
68-
30%
64
72
57-
65-
74-
40%
61
69
78
52-
63-
71 -
60%
56
67
75
45-
57-
65-
80%
50
61
69