ONAN MOTOR GENERATOR
24C- 3
4A .
K2 contact is defective . Replace printed circuit board .
-
-
5A .
Jumper terminal 7 to 1 . Does engine crank?
6A
7A
6A .
Start switch S3 is defective . Replace printed circuit board .
-
-
7A .
Jumper from S terminal of 1311 starter motor to positive (+) . Does engine
crank?
8A
9A
8A.
Replace K1 start solenoid .
-
-
9A.
Starter is defective . Remove and perform tests listed in STARTING
SYSTEM section and/or replace starter.
-
-
10A .
Replace battery .
-
-
B .
ENGINE CRANKS BUT DOES NOT START
YES
NO
1 B .
Is F1 fuse on control board OK?
313
213
213 .
Replace with an identical 5 amp fuse . Correct problem which caused fuse
to burn . (NOTE : Remote control leads maybe shorted or grounded) .
-
-
313 .
While engine cranks, check K1-I start solenoid voltage . Is 12 volts present
between terminals 10 and 1?
513
413
4B .
Replace K1 start solenoid .
-
-
513 .
Jumper terminals 9 to 11 . Does engine start when start switch is pushed?
613
713
613 .
K2 contacts are defective . Replace printed circuit board .
-
-
713 .
Fuel solenoid K4 must be open during starting and running . Remove fuel
line from carburetor. Does fuel pulsate from line when start switch is
pushed?
11B
813
WARNING : Use extreme care for tests 7B and 8B . Direct the fuel flow into
a suitable container and make sure area is well ventilated to prevent
accumulation of gasoline fumes.
8B . .
Disconnect fuel solenoid from line and check fuel pump E2 . Pump will
click when operating properly . Does fuel pulsate from pump (solenoid
disconnected) when start switch is pushed?
10B
913
913 .
Fuel pump (or wiring) is defective and must be replaced .
-
-
1013 .
Fuel solenoid is defective and must be replaced .
-
-
11B .
Is electric choke closed when engine is cranking?
13B
12B
12B .
Voltage at choke terminal when engine is cranking should be 12 volts . If
choke does not move (at room temperature) with 12 volts applied, replace
it . Also check wire from choke to control for shorts to ground.
-
-
13B .
The fault is in the ignition system . Check points, plugs, wires and coil .
Refer to IGNITION section .
-
-