GMC 1976 ZEO 6083 Maintenance Manual page 684

Table of Contents

Advertisement

ONAN MOTOR GENERATOR
24C- 7
GENERATOR TROUBLE DIAGNOSIS
Engine starts hard .
1 . Improper adjustment .
1 . Set idle & power needles at 1
turn open . After engine starts and
runs, set for optimum performance.
2 . No fuel in carburetor .
2. Check carburetor drain valve. If
no fuel in bowl clean tank filter
and carburetor . Check electric fuel
pump operation, check electric
solenoid valve.
3 . Choke valve not
3 . Check controls for proper travel .
closing.
Governor Surge
1 . Throttle shaft and
1 . Remove and replace shaft if worn .
valve binding.
Clean carburetor body . Reassemble
throttle shaft assembly into carbu-
retor body as far as possible . Hold
firmly in place in this position
while assembling throttle valve.
Make certain valve does not bind in
throttle bore when opening and
closing throttle .
Lean carburetion.
2. Adjust carburetor .
Problem
Possible Cause
Correction
No AC output voltage.
1 . Blown fuse or cir-
1 . Replace fuse or reset breaker
cuit breaker.
and look for cause.
2. Disconnected wire or
2. Reconnect wire or wires.
lead on brushes, bridge
rectifier or reactor
assembly .
3. Brushes not making
3 . Check brush springs for free
-
contact with collector
movement or brushes which may be
rings.
excessively worn .
4. Open, grounded or
4. Test with series test lamp and
short circuit in field
repair or replace as necessary.
or armature winding.
5. Defective bridge rec-
5 . Test with ohmmeter and replace
tifier assembly.
if defective.
6. Bridge rectifier as-
6. Reinstall making sure marks on
sembly installed wrong in
case and rectifier match.
its case .