Serial Port A - Sun Microsystems Ultra 60 Service Manual

Hide thumbs Also See for Ultra 60:
Table of Contents

Advertisement

CODE EXAMPLE 4-15
CODE EXAMPLE 4-15
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===> 6
TEST='parallel_port_test'
SUBTEST='dma_read'
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===>
4.7.8

Serial Port A

The serial port A diagnostic invokes the uart_loopback test. The
uart_loopback test transmits and receives 128 characters and checks the
transaction validity. The following baud rates are tested in asynchronous mode:
460800, 307200, 230400, 153600, 76800, 57600, 38400, 19200, 9600, 4800, 2400, and 800.
CODE EXAMPLE 4-16
CODE EXAMPLE 4-16
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===> 7
TEST='uarta_test'
BAUDRATE='1200'
SUBTEST='internal_loopback'
BAUDRATE='1800'
SUBTEST='internal_loopback'
BAUDRATE='2400'
SUBTEST='internal_loopback'
BAUDRATE='4800'
SUBTEST='internal_loopback'
BAUDRATE='9600'
SUBTEST='internal_loopback'
BAUDRATE='19200'
SUBTEST='internal_loopback'
BAUDRATE='38400'
SUBTEST='internal_loopback'
BAUDRATE='57600'
SUBTEST='internal_loopback'
BAUDRATE='76800'
SUBTEST='internal_loopback'
BAUDRATE='115200'
SUBTEST='internal_loopback'
BAUDRATE='153600'
identifies the parallel port output message.
Parallel Port Output Message
identifies the serial port A output message.
Serial Port A Output Message
Chapter 4 Troubleshooting Procedures
4-19

Advertisement