Table 4-1 Internal Drives Identification - Sun Microsystems Ultra 60 Service Manual

Hide thumbs Also See for Ultra 60:
Table of Contents

Advertisement

Symptom
A hard drive read, write, or parity error is reported by the operating system or
customer application.
A CD-ROM drive read error or parity error is reported by the operating system or
customer application.
Action
Replace the drive indicated by the failure message. The operating system identifies
the internal drives as listed in
TABLE 4-1
Operating System Address
c0t0d0s#
c0t1d0s#
c0t6d0s#
c0t5d0s#
Note – The # symbol in the operating system address examples may be a numeral
between 0 and 7 that describes the slice or partition on the drive.
Symptom
Hard drive or CD-ROM drive fails to respond to commands.
Note – To bypass POST, type: setenv diag-switch? false at the ok prompt.
Action
Test the drive response to the probe-scsi command as follows:
1. At the system ok prompt:
a. Type reset-all.
b. Type probe-scsi.
4-4
Sun Ultra 60 Service Manual • August 2001
TABLE 4-1
Internal Drives Identification
.
Drive Physical Location and Target
Lower hard drive, target 0
Upper hard drive, target 1
CD-ROM drive, target 6 (optional)
Tape drive, target 5 (optional)