CODE EXAMPLE 3-3
0> <00> SC Dtag Init
0> <00> Probe Memory
0>INFO:128MB Bank 0
0>INFO:No memory detected in Bank 1
0>INFO:No memory detected in Bank 2
0>INFO:No memory detected in Bank 3
0> <00> Malloc Post Memory
0> <00> Init Post Memory
0> <00> Post Memory Addr Test
0>mem_utils.c mem_err_bd_desc = 00000000.00000000, xor =
80808000.80808080
0>STATUS =FAILED
0>TEST
TTF
PASSES =1
ERRORS =1
SUSPECT=SIMM U0801
0>MESSAGE=Mem Addr line compare error
0> xor
0> Verbose Data Path Information:
0> Addr = 00000000.00000000
0> PATH SUSPECT= SDB U0301
0> PATH SUSPECT= XBAR U301
0> <00>Memory Stack Test
0>STATUS =FAILED
0>TEST
TTF
PASSES =1
ERRORS =1
SUSPECT=SIMM U0801
0>MESSAGE=Memory compare error
3-20
Sun Ultra 60 Service Manual • August 2001
Typical Error Code Failure Message (Continued)
=Post Memory Addr
=0
addr 00000000.00000000
exp
00000000.00000000
obs
80808000.80808080
80808000.80808080
=Post Memory Addr
=0
addr 00000000.007f8080
exp
55555555.557fd5d5
obs
15151515.15151505