Transport
Tube
Toner End
Sensor
When a toner bottle is installed, the transport tube pushes the shutter.
This opens the bottle, and toner can flow from the bottle.
The spiral grooves in the bottle allow the bottle to rotate and help to
feed toner out of the bottle.
The toner flows through the toner end sensor.
This slide shows how toner is supplied from the toner bottle.
Toner near-end and end detection were discussed in the Process Control section of
the course.
Toner Bottle
Shutter
Toner
Bottle