Temperature Control Components
Thermopile
Thermistor
Thermostat
Heating
Roller
The following components control temperature in the
fusing unit:
Heating roller: Thermistor and thermostat
Pressure roller: Thermistor and thermostat
Above the fusing unit: Thermopile
Pressure
Roller
Thermostat
Thermistor