Cleanliness; Interference; Power - DEC Personal DECstation 5000 User Manual

Hide thumbs Also See for Personal DECstation 5000:
Table of Contents

Advertisement

The Environment
2.1 Site Requirements
Air should flow freely around your workstation to keep heat from building
up and damaging the equipment.
Leave 4 inches (10 centimeters) between system unit vents and other
objects.
Leave 3 inches (7.6 centimeters) between monitor vents and other objects.
Relative humidity should be between 10 and 80 percent.
Store supplies (such as tape cartridges) within these same temperature and
humidity limits.

2.1.2 Cleanliness

Keep your work area as dust-free as possible.

2.1.3 Interference

Set up your workstation at least 30 inches (76.2 centimeters) from any
sources of electrical interference, such as other terminals or monitors,
printers, or electric pencil sharpeners.
To limit its exposure to static electricity and magnetized objects, set up
your workstation away from busy corridors and other high-traffic areas and
away from filing cabinets and steel beams in walls.

2.1.4 Power

Reserve an entire circuit for your workstation power source. The fuse for
the circuit must be at least 15 amperes.
Be sure your electrical circuit is properly grounded and free from electrical
noise. If possible, connect a surge-protected power strip to the outlet and
plug your workstation power cord into the power strip.
Be sure the voltage of the devices you connect to your workstation matches
the voltage of your power source (see the following section, ''Section 2.2'').
2–2 The Environment