DMD20/DMD20 LBST Universal Satellite Modem
Turn on the unit by placing the Rear Panel Switch (located above the power entry connector) to
the On Position. Upon initial and subsequent power-ups, the DMD20 Microprocessor will test
itself and several of its components before beginning its Main Monitor/Control Program. These
power-up diagnostics show no results if successful. If a failure is detected, the Fault LED will
illuminate.
The initial field checkout of the modem can be accomplished from the Front Panel or in the
Terminal Mode. The Terminal Mode has the advantage of providing full screen access to all of
the modem's parameters, but requires a separate terminal or computer running a Terminal
Program. The Terminal Mode is enabled from the front panel in the System M&C Submenus.
2.5.2 Factory Terminal Setup
The factory terminal setup is as follows:
Emulation Type:
Baud Rate:
Data Bits:
Parity:
Stop Bits:
2.6 Storage
It is recommended that the unit be stored in its original sealed packing. The unit should be stored
in a dry location where the temperature is stable, away from direct contact with rain, snow, wind,
sun, or anything that may cause damage.
TM103 – Rev. 2.5
VT-100 (can be changed)
19.2 K (Can be changed via Front Panel)
8
No Parity (Fixed)
1 Stop Bit
Installation
2-5