Configuration
Setting the RF Transmit Status
This setting can block a unit (or link) from carrying data traffic. It is used to disable units and to discontinue
service to customers if necessary.
➧
To set RF transmit status
1. From the Main Menu, select RF Station Configuration and press
Configuration menu is displayed.
Operating Mode
RF Transmit Status
Link Monitor Period (0=OFF, 1-10000)
Test Mode Timer Minutes (1-1000)
Base Station Only Parameters
Maximum Remote Distance
Link Monitor Remote Station Rank
Remote Station Only Parameters
Throttle Enable
Throttle Level (1-50)
2. Select RF Transmit Status and press
3. Select a setting.
unblocked
blocked
4. Press
.
Enter
5. Press
to exit to the Main Menu.
Esc
58
RF Station Configuration
. The data field highlights.
Enter
Unit passes data in both directions(default setting)
Will not pass data in either direction
. The RF Station
Enter
Normal Mode
-> unblocked
0
5
5 Km
1
off
1
Hopper Plus 120-24 Installation & Configuration Guide