Setting Config Test Minutes
When changing Radio Module Configuration settings, you may enter settings that cause a unit or system to
not function as expected. If this happens, you can return to the last-saved settings if you first set the Config Test
Minutes test period. When this test period expires, the unit automatically reboots and returns to its last-saved
flash memory settings. The time period can be fixed from 1 to 120 minutes.
Tip: To begin, enter a time period of 30 minutes. If the time period is too short, you will not have enough
time to make configuration changes and save them to flash ROM. If the time period is long, you will have to
wait a long time before the unit automatically reboots and restores the settings to the original flash ROM
state.
To set the config test timeout period
1. From the Main Menu, select Radio Module Configuration and press
Configuration menu is displayed.
Station Type
Station Rank (1-1000)
Center Frequency
Security Password 1
Security Password 2
Security Password 3
Security Password 4
Security Password 5
Scrambling Code
Acquisition Code
Config Test Minutes
Base Station Only Parameters
Repeater Mode
System Symmetry Type
Dynamic Polling Level (1-100)
Remote Station Only Parameters
Remote Unit RF Group (0-63)
Reboot New RF configuration
Save Current Config to Flash
2. Select Config Test Minutes and press
3. Type the number of minutes (1-120) and press
4. Select Reboot New RF Configuration and press
120-24 Login menu is displayed. The unit will now use the current settings to operate, for the length of
time specified by the Current Test Minutes.
5. To save the current setting(s) to flash memory, log in, go to the Main Menu, and select Radio Module
Configuration, Save Current Config to Flash. See
Configurations, page
6. Press
to exit to the Main Menu.
Esc
DEC 2000 Rev 02
Radio Module Configuration
(Hex)
(Hex)
(Hex)
(Hex)
(Hex)
(Hex)
(0-15)
(1-120)
-> 30
79.
New
Current
Remote Unit
Remote Unit
1
1
2.4400 GHz
2.4400 GHz
1
1
10
10
100
100
1000
1000
10000
10000
0
0
0
0
30
off
off
Asymmetric
Asymmetric
1
0
0
Press Enter to Execute
Press Enter to Execute
. The data field highlights.
Enter
. The number of minutes is stored in the New state.
Enter
. The unit reboots and the Hopper Plus
Enter
Radio Module Configuration
. The Radio Module
Enter
Flash
Remote Unit
1
2.4400 GHz
1
10
100
1000
10000
0
0
30
off
Asymmetric
0
Rebooting and Saving RF Module
65