Performing Link Monitor Test (Normal Mode)

The link monitor test can be run from either a base station or a remote unit that is set to Normal Mode. The
test operates in parallel with the message stream, so it consumes some of the link's total data capacity. You
can control the ratio of test data to message data (and thereby control the amount of test data overhead) by
setting the link monitor period. See
Note: Link monitor test stays in effect even if you power cycle or reboot units, so you must turn it off using
the Link Monitor Period (0 = OFF) setting.
To perform Link Monitor test from a base station
1. Connect the test PC to the MANAGEMENT port of the base station. See
Performing RF
Tests, page 50.
2. Log in to the unit and go to the Main Menu.
3. Select RF Station Configuration and press
displayed.
Operating Mode
RF Transmit Status
Link Monitor Period (0=OFF, 1-10000)
Test Mode Timer Minutes (1-1000)
Base Station Only Parameters
Maximum Remote Distance
Link Monitor Remote Station Rank
Remote Station Only Parameters
Throttle Enable
Throttle Level (1-50)
4. Select Operating Mode and press
5. Press the arrow keys to select Normal mode and press
6. Select RF Transmit Status and press
7. Press the arrow keys to select unblocked and press
8. Select Link Monitor Remote Station Rank and press
9. Type the rank of the remote unit that you want to link to and press
number of the remote unit. The rank of a remote can be any number from 1 – 1000. See
Station
Rank, page 67.)
10. Select Link Monitor Period and press
11. Type a link monitor period (1) and press
entered in the field. (A setting of 1 means that 50% of all data is test data.)
52
Setting the Link Monitor
Period, page 59 for more information.
Enter
RF Station Configuration
. The data field highlights.
Enter
. The data field highlights.
Enter
Enter
. The data field highlights.
Enter
. Link Monitor starts as soon as a non-zero value is
Enter
General Equipment Setup for
. The RF Station Configuration menu is
-> Normal Mode
unblocked
0
5
5 Km
1
off
1
.
Enter
.
The data field highlights.
Enter.
. (The rank is the identification
Enter
Hopper Plus 120-24 Installation & Configuration Guide